Popular Posts

Showing posts with label megacli command cheat sheet. Show all posts
Showing posts with label megacli command cheat sheet. Show all posts

Monday, May 12, 2014

MegaCli Commands

Adapter parameter -aN
The parameter -aN (where N is a number starting with zero or the string ALL) specifies the PERC5/i adapter ID. If you have only one controller it’s safe to use ALL instead of a specific ID, but you’re encouraged to use the ID for everything that makes changes to your RAID configuration.

Physical drive parameter -PhysDrv [E:S]
For commands that operate on one or more pysical drives, the -PhysDrv [E:S] parameter is used, where E is the enclosure device ID in which the drive resides and S the slot number (starting with zero). You can get the enclosure device ID using "MegaCli -EncInfo -aALL". The E:S syntax is also used for specifying the physical drives when creating a new RAID virtual drive.

Virtual drive parameter -Lx
The parameter -Lx is used for specifying the virtual drive (where x is a number starting with zero or the string all).

Controller information
MegaCli -AdpAllInfo -aALL
MegaCli -CfgDsply -aALL
MegaCli -AdpEventLog -GetEvents -f events.log -aALL && cat events.log
Enclosure information
MegaCli -EncInfo -aALL
Virtual drive information
MegaCli -LDInfo -Lall -aALL
Physical drive information
MegaCli -PDList -aALL
MegaCli -PDInfo -PhysDrv [E:S] -aALL
Battery backup information
MegaCli -AdpBbuCmd -aALL
Controller management

Silence active alarm
MegaCli -AdpSetProp AlarmSilence -aALL
Disable alarm
MegaCli -AdpSetProp AlarmDsbl -aALL
Enable alarm

MegaCli -AdpSetProp AlarmEnbl -aALL
Physical drive management


Set state to offline
MegaCli -PDOffline -PhysDrv [E:S] -aN
Set state to online
MegaCli -PDOnline -PhysDrv [E:S] -aN
Mark as missing

MegaCli -PDMarkMissing -PhysDrv [E:S] -aN
Prepare for removal
MegaCli -PdPrpRmv -PhysDrv [E:S] -aN
Replace missing drive

MegaCli -PdReplaceMissing -PhysDrv [E:S] -ArrayN -rowN -aN
The number N of the array parameter is the Span Reference you get using "MegaCli -CfgDsply -aALL" and the number N of the row parameter is the Physical Disk in that span or array starting with zero (it’s not the physical disk’s slot!).

Rebuild drive
MegaCli -PDRbld -Start -PhysDrv [E:S] -aN
MegaCli -PDRbld -Stop -PhysDrv [E:S] -aN
MegaCli -PDRbld -ShowProg -PhysDrv [E:S] -aN
Clear drive
MegaCli -PDClear -Start -PhysDrv [E:S] -aN
MegaCli -PDClear -Stop -PhysDrv [E:S] -aN
MegaCli -PDClear -ShowProg -PhysDrv [E:S] -aN
Bad to good (or back to good as I like to call it)
MegaCli -PDMakeGood -PhysDrv[E:S] -aN
This changes drive in state Unconfigured-Bad to Unconfigured-Good.

Walkthrough: Change/replace a drive

Set the drive offline, if it is not already offline due to an error
MegaCli -PDOffline -PhysDrv [E:S] -aN
Mark the drive as missing
MegaCli -PDMarkMissing -PhysDrv [E:S] -aN
Prepare drive for removal
MegaCli -PDPrpRmv -PhysDrv [E:S] -aN
Change/replace the drive

If you’re using hot spares then the replaced drive should become your new hot spare drive:
MegaCli -PDHSP -Set -PhysDrv [E:S] -aN
In case you’re not working with hot spares, you must re-add the new drive to your RAID virtual drive and start the rebuilding

MegaCli -PdReplaceMissing -PhysDrv [E:S] -ArrayN -rowN -aN
MegaCli -PDRbld -Start -PhysDrv [E:S] -aN